Skip to content
Test versionSearch

Motoring

Battery runtime calculator

Estimate how many hours a battery can run a steady load from its capacity in Wh or Ah, the power draw, efficiency and reserve. Temperature, age and peak power can shorten the runtime.

How it worksFAQRelated tools

Content reviewed:

Also available for Germany, in German 

Enter capacity in Wh or Ah, voltage when using Ah, power draw and your own efficiency and reserve assumptions. Download your entered values, complete results and schedule tables as JSON or a separate printable HTML file.

A planning estimate for a constant load. Check the battery and inverter instructions; temperature, age and peak power can shorten runtime.

How it works

Nominal Wh = Wh or Ah × V. Usable Wh = nominal Wh × (1 − wear) × efficiency × (1 − reserve). Hours = usable Wh ÷ total W. The separate energy-to-charge form accepts your non-negative energy in kWh and a positive voltage in V on a confirmed common basis. It multiplies kWh by 1000000, then divides by the supplied voltage to give an algebraic mAh charge equivalent. There is no default voltage. An instantaneous or open-circuit voltage is not automatically a suitable basis for changing voltage. The result is not a rated or usable capacity, charging profile, runtime, loss estimate or compatibility decision. This separate form does not implement every Ah-to-kWh or charging-time workflow.

Worked example

1200 Wh × 90% × 80% ÷ 100 W = 8.64 h.

Worked example

With these example values the calculator gives the result below. You can change any value in the form above.

Inputs

Capacity unit
Wh
Capacity (Wh or Ah)
1200
Nominal voltage
12
Main load (W)
100
System efficiency (%)
90
Remaining reserve (%)
20
Second device power (W)
0
Number of second devices
0
Capacity loss from wear (%)
0
Peak power
0
Inverter limit
0

Result

Estimated runtime
8.64 h
Estimated minutes
518 min
Usable energy
864 Wh
Nominal energy
1,200 Wh
Total load
100 W

Frequently asked questions

How do I calculate battery runtime?

Nominal Wh = Wh, or Ah × V. Usable Wh = nominal Wh × (1 − wear) × efficiency × (1 − reserve). Hours = usable Wh ÷ total W.

How long will a 1200 Wh battery run a 100 W load?

With 90% efficiency and a 20% reserve, 1200 Wh × 90% × 80% ÷ 100 W gives 8.64 hours, or 518 minutes.

Can I enter battery capacity in Ah?

Yes. When you use Ah, also enter the nominal voltage so the battery runtime calculator can convert it to Wh.

Why can real battery runtime be shorter?

The result is a planning estimate for a constant load. Temperature, age and peak power can shorten runtime, so check the battery and inverter instructions.

Can I add more devices or an inverter limit?

Yes. Optional fields cover a second device power and count, capacity loss from wear, peak power and an inverter limit.

How do I convert kWh to mAh?

A separate form multiplies your kWh by 1000000 and divides by your own positive reference voltage to give an algebraic mAh charge equivalent. It has no default voltage and is not a rated or usable capacity.