Skip to content
Test versionSearch

Home and energy

Water heat store with constant properties

Calculate the sensible heat stored in a water tank from volume and temperatures between 0 and 100 °C, and the runtime at a constant load.

How it worksFAQRelated tools

Content reviewed:

Edit the example values, press Calculate and download the result if you need it. Editing or resetting clears the result; nothing is automatically saved.

Single-phase sensible heat only, entered temperatures 0–100 °C and constant density/specific heat. Examples are assumptions, not certified water properties. Loss percent is deducted once; constant loss kW then joins the constant useful load. No cooling curve, stratification, phase change, pressure or installation design. Zero heat gives zero runtime; positive heat and zero load have no finite depletion time in this model. For ideal water heating time, set One-time unavailable heat fraction and Constant heat loss to 0. Lower and Upper temperatures are your start and target. Enter a positive Constant useful heat load as the constant net power delivered to that same water, not an assumed appliance rating. Read Constant-load runtime (hours) as ideal heating hours. Only the entered water is modelled. The loss fields describe depletion, not heating efficiency. Small positive times may display as 0; exports keep the source value.

Decimal results are approximate. Inputs stay in this browser tab.

How it works

Plain arithmetic on the figures you enter; the result lists every input and output. No national tax rules or official tariffs are applied. Single-phase sensible heat only, entered temperatures 0–100 °C and constant density/specific heat. Examples are assumptions, not certified water properties. Loss percent is deducted once; constant loss kW then joins the constant useful load. No cooling curve, stratification, phase change, pressure or installation design. Zero heat gives zero runtime; positive heat and zero load have no finite depletion time in this model.

Worked example

With these example values the calculator gives the result below. You can change any value in the form above.

Inputs

Water volume (litres)
1000
Entered constant density
1000
Entered constant specific heat
4.184
Lower temperature (°C, 0–100)
10
Upper temperature (°C, 0–100)
50
One-time unavailable heat fraction (%)
10
Constant useful heat load (kW)
4
Constant heat loss (kW)
0.2
Display decimal places (0–8)
2

Result

Water volume (litres)
1000
Water mass (kg)
1000
Temperature difference (K)
40
Sensible heat (kWh)
46.49
Available heat after one-time loss (kWh)
41.84
Total constant heat load (kW)
4.2
Constant-load runtime (hours)
9.96
No finite depletion time in this model
No

Frequently asked questions

How much heat does a hot water tank store?

The water heat store calculator multiplies the water mass by your entered specific heat and the temperature difference, which gives the stored sensible heat in kWh. The worked example is editable and its inputs determine the result.

How long will stored hot water last under a constant load?

The available heat after the one-time loss is divided by the total constant load in kW. The result is the constant-load runtime in hours.

How do I calculate how long it takes to heat water?

Set the one-time unavailable heat fraction and constant heat loss to 0, enter start and target temperatures and a positive constant useful heat load as net power. Read the constant-load runtime as ideal heating hours.

How are heat losses handled in the water heat store?

The loss percent is deducted once from the stored heat. A constant loss in kW is then added to the constant useful load. The loss fields describe depletion, not heating efficiency.

What temperature range does the water heat calculator accept?

Temperatures from 0 to 100 °C, for single-phase sensible heat only, with constant density and specific heat that you enter. Examples are assumptions, not certified water properties.

What does the water heat store not model?

There is no cooling curve, stratification, phase change, pressure or installation design. With positive heat and zero load there is no finite depletion time.