U-value calculator for wall and roof layers

Calculate series resistance, U-value and continuous extra thickness for your own numerical target.

How it worksFAQRelated tools

Content reviewed:

Edit the example values, press Calculate and download the result if you need it. Editing or resetting clears the result; nothing is automatically saved.

Every prefilled number is an arbitrary hypothetical example, not a material specification, climate value, prescribed surface resistance or legal U-value. Enter verified operating conductivity and both surface resistances yourself. Only homogeneous flat layers in series and fixed temperatures are modelled. Negative heat flow means the opposite direction; negative energy is signed transfer, not purchased energy. Additional thickness is continuous algebra, not a chosen product or approved insulation. Thermal bridges, air gaps, moisture, ground, ventilation, workmanship and building regulations are outside the calculation. Long layer lists in CSV/TXT are shown as numbered JSON text parts. Decode each quoted part separately and join in order to recover the complete list; native JSON retains the full original layer list. Separate entered convection balance uses Qconv/(A*deltaT), not the wall U-value. Supply the convective heat component and surface-minus-bulk-fluid temperature difference yourself. No correlation or material lookup; results and CSV/TXT are separate.

Decimal results are approximate. Inputs stay in this browser tab.

How it works

Heat arithmetic on the values you enter, with every input and result recorded exactly. It does not select a radiator or check building regulations. Every prefilled number is an arbitrary hypothetical example, not a material specification, climate value, prescribed surface resistance or legal U-value. Enter verified operating conductivity and both surface resistances yourself. Only homogeneous flat layers in series and fixed temperatures are modelled. Negative heat flow means the opposite direction; negative energy is signed transfer, not purchased energy. Additional thickness is continuous algebra, not a chosen product or approved insulation. Thermal bridges, air gaps, moisture, ground, ventilation, workmanship and building regulations are outside the calculation. A separate UK entered convection balance gives h=Qconv/(A*(Ts-Tbulk)), with positive Qconv from surface to bulk fluid. Signed Qconv and deltaT must agree unless Qconv is zero; area is positive and deltaT nonzero. No radiation separation or fluid-flow correlation. This coefficient is separate from the wall U-value and keeps its own results and CSV/TXT.

Worked example

With these example values the calculator gives the result below. You can change any value in the form above.

Inputs

Entered inside surface resistance (m²·K/W)
0.2
Entered outside surface resistance (m²·K/W)
0.3
Own numerical U target
0.2
Entered added-layer conductivity (W/(m·K))
0.05
Entered area (m²)
10
Inside temperature (°C)
20
Outside temperature (°C)
0
Constant-condition period (hours)
2
Display decimal places (0–8)
2

Result

Entered layers
2
Layer resistance total (m²·K/W)
3
Inside surface resistance (m²·K/W)
0.2
Outside surface resistance (m²·K/W)
0.3
Total series resistance (m²·K/W)
3.5
Entered/model U (W/(m²·K))
0.29
Own numerical U target (W/(m²·K))
0.2
Own numerical target met
0
Additional resistance to own target (m²·K/W)
1.5
Entered extra conductivity (W/(m·K))
0.05
Continuous extra thickness
75
Entered area
10

Frequently asked questions

How do I calculate the U-value of a wall or roof?

Enter each layer with its thickness in mm and thermal conductivity in W/(m·K), plus both surface resistances. The U-value calculator adds the layer resistances in series and returns the U-value.

Can the U-value calculator tell me how much insulation to add?

It calculates a continuous extra thickness needed for your own numerical target. This is algebra only, not a chosen product or approved insulation.

Are the prefilled values real material data?

No. Every prefilled number is an arbitrary hypothetical example, not a material specification, climate value, prescribed surface resistance or legal U-value. Enter verified conductivities and surface resistances yourself.

What does the U-value calculation not include?

Only homogeneous flat layers in series at fixed temperatures are modelled. Thermal bridges, air gaps, moisture, ground, ventilation, workmanship and building regulations are outside the calculation.

How do I calculate a convective heat transfer coefficient?

A separate form uses h = Qconv ÷ (A × (Ts − Tbulk)) from your entered convective heat rate, area and surface-minus-fluid temperature difference. It is separate from the wall U-value.