Home and energy
Room heat loss calculator
Calculate room heat loss from your own area or volume assumption, or add up surface heat transfers with manual losses and gains for one room.
Edit the example values, press Calculate and download the result if you need it. Editing or resetting clears the result; nothing is automatically saved.
Result
Formula / calculation:
Every prefilled value is an arbitrary hypothetical example. No building-category rates, climate assumptions, statutory limits or automatic corner-room reserve are supplied. Entered W/m² and W/m³ are different assumptions; select the intended mode. The surface ledger retains signed flows, including gains from warmer adjoining spaces. Additional losses and internal gains are manual watts, not a ventilation or occupancy model. Negative net demand becomes zero heating, while signed transmission remains visible. Your reserve percentage is an explicit scenario. Constant-power energy is not a forecast of actual use. This does not choose or certify a radiator, heat pump or heating design, perform manufacturer temperature corrections or assess UK/DE building compliance. Long surface lists in scenario CSV/TXT are stored as numbered JSON text parts; decoding each part and joining in order recovers the complete original input. Native JSON keeps the full list.
Decimal results are approximate. Inputs stay in this browser tab.
How it works
Heat arithmetic on the values you enter, with every input and result recorded exactly. It does not select a radiator or check building regulations. Every prefilled value is an arbitrary hypothetical example. No building-category rates, climate assumptions, statutory limits or automatic corner-room reserve are supplied. Entered W/m² and W/m³ are different assumptions; select the intended mode. The surface ledger retains signed flows, including gains from warmer adjoining spaces. Additional losses and internal gains are manual watts, not a ventilation or occupancy model. Negative net demand becomes zero heating, while signed transmission remains visible. Your reserve percentage is an explicit scenario. Constant-power energy is not a forecast of actual use. This does not choose or certify a radiator, heat pump or heating design, perform manufacturer temperature corrections or assess UK/DE building compliance.
Worked example
With these example values the calculator gives the result below. You can change any value in the form above.
Inputs
- Scenario method
- Entered W/m²
- Room floor area (m²)
- 20
- Room height (m)
- 3
- Own entered rate
- 40
- Own scenario reserve (%)
- 10
- Constant-power period (hours)
- 2
- Display decimal places (0–8)
- 2
Result
- Entered area
- 20
- Room volume
- 60
- Signed surface transmission
- Undefined
- Scenario heating before reserve (W)
- 800
- Own reserve (%)
- 10
- Own reserve power (W)
- 80
- Scenario heating including own reserve (W)
- 880
- Entered constant period (h)
- 2
- Scenario energy transfer/use
- 1.76
Frequently asked questions
How do I estimate the heat loss of a room?
Choose a mode: an entered W/m² rate times the floor area, an entered W/m³ rate times the room volume, or a surface ledger of entered heat transfers plus manual losses and gains. The room heat loss calculator then adds your own reserve percentage.
What is the difference between W/m² and W/m³ in a heat loss estimate?
They are different assumptions. W/m² is applied to the entered area and W/m³ to the room volume, so you need to select the mode that matches the value you have.
Can heat gains from a warmer neighbouring room be included?
Yes. The surface ledger keeps signed flows, including gains from warmer adjoining spaces. Additional losses and internal gains are entered as manual watts.
What happens if gains are larger than losses?
Negative net demand becomes zero heating in the room heat loss calculator, while the signed transmission remains visible in the results.
Does the room heat loss calculator supply U-values or climate data?
No. Every prefilled value is an arbitrary example, and no building-category rates, climate assumptions, statutory limits or automatic corner-room reserve are supplied.
Can the result be used to choose a radiator or heat pump?
No. The calculator does not choose or certify a radiator, heat pump or heating design, perform manufacturer temperature corrections or assess UK or German building compliance.