DC cable size calculator (voltage drop)
Check DC cable sizes for voltage drop by comparing conductor areas for an equal two-wire loop, with your own resistivity and current.
Edit the example values, press Calculate and download the result if you need it. Editing or resetting clears the result; nothing is automatically saved.
Result
Formula / calculation:
All prefilled numbers are arbitrary hypothetical examples. Enter operating resistivity and actual candidate conductor areas, not an insulated cable outside diameter. Both conductors have equal length, area and resistivity. Continuous area is an algebraic threshold, not a chosen standard cable size. Rows remain in your order; no recommended cable is selected. No ampacity, protection, earthing, joint/termination, temperature, grouping, short-circuit or installation safety check. Candidate drops exceeding source voltage are outside the model: receiving voltage is undefined and the criterion is not met. A zero threshold at zero load or length does not establish a usable conductor. UK/DE legal and standards checks remain separate. CSV/TXT scenarios contain complete longer conductor-area candidate lists in numbered parts. Each part is a JSON-quoted string: parse each part as JSON and join the strings in numbered order to recover the exact entered list. Native JSON retains the full original list directly. Optional DC power conversion is an entry utility: Convert, then Apply current and press Calculate. The main record contains voltage and applied current; power entered in the separate utility is not included. Changing voltage or power does not automatically update the current field.
Decimal results are approximate. Inputs stay in this browser tab.
How it works
Electrical arithmetic on the values you enter, with every input and result recorded exactly. It does not design an installation, select a cable or check national regulations. All prefilled numbers are arbitrary hypothetical examples. Enter operating resistivity and actual candidate conductor areas, not an insulated cable outside diameter. Both conductors have equal length, area and resistivity. Continuous area is an algebraic threshold, not a chosen standard cable size. Rows remain in your order; no recommended cable is selected. No ampacity, protection, earthing, joint/termination, temperature, grouping, short-circuit or installation safety check. Candidate drops exceeding source voltage are outside the model: receiving voltage is undefined and the criterion is not met. A zero threshold at zero load or length does not establish a usable conductor. UK/DE legal and standards checks remain separate.
Worked example
With these example values the calculator gives the result below. You can change any value in the form above.
Inputs
- Entered DC source voltage (V)
- 24
- Entered DC current (A)
- 10
- One-way route length (m)
- 10
- Actual operating resistivity (Ω·mm²/m)
- 0.02
- Own entered voltage-drop criterion
- 10
- Display decimal places (0–8)
- 2
Result
- Entered voltage (V)
- 24
- Entered current (A)
- 10
- One-way route (m)
- 10
- Entered resistivity (Ω·mm²/m)
- 0.02
- Entered drop budget (V)
- 2.4
- Algebraic continuous area threshold
- 1.67
- Entered candidates
- 3
- Candidates meeting entered drop criterion only
- 2
Frequently asked questions
What does the DC cable size calculator calculate?
It compares your named candidate conductor areas against one mathematical voltage-drop criterion for an equal two-wire DC loop. Results stay in the order you enter and no cable is recommended.
Which assumptions does the voltage-drop model use?
Both conductors have equal length, area and resistivity. You enter operating resistivity and actual candidate conductor areas, not an insulated cable outside diameter.
Does the calculator choose a standard cable size?
No. The continuous area is an algebraic threshold, not a chosen standard cable size, and rows remain in your order with no recommended cable selected.
Does the tool check ampacity or installation safety?
No. It includes no ampacity, protection, earthing, joint or termination, temperature, grouping, short-circuit or installation safety check. UK and DE legal and standards checks remain separate.
What happens if the voltage drop exceeds the source voltage?
Such candidates are outside the model: the receiving voltage is undefined and the criterion is not met.
Can I convert DC power to current in the calculator?
Yes, with the optional utility: Convert using the voltage, then Apply current and press Calculate. The power entered there is not included in the main record, and changing voltage or power does not update the current field.
Are the prefilled numbers real recommendations?
No. All prefilled numbers are arbitrary hypothetical examples, so edit them with your own values. Editing or resetting clears the result and nothing is saved automatically.