Home and energy

Voltage drop calculator

Calculate voltage drop along a cable from route length, current, operating resistance and reactance, and compare it with your chosen limit.

How it worksFAQRelated tools

Content reviewed:

Edit the example values, press Calculate and download the result if you need it. Editing or resetting clears the result; nothing is automatically saved.

All prefilled numbers are arbitrary hypothetical examples, not cable specifications or approved limits. Enter one-way route length; return is included once for DC and single-phase. Enter real W, not VA; three-phase voltage is line-to-line and loads must be balanced. AC assumes lagging power factor and a steady scalar approximation. Leading, unbalanced, harmonic and starting conditions are outside this model. Operating R/X must come from your own verified conductor data. Upstream drop consumes the entered budget. No upper mathematical length for zero coefficient does not imply a safe infinite cable. Not defined means either no finite bound or an already exhausted budget; check the separate flags. A zero receiving voltage is a numerical endpoint, not a usable design. No thermal ampacity, protection, earthing, short-circuit, installation or country-law approval. Scenario CSV/TXT keep an undefined maximum length explicit: either no finite length bound in the entered model, or the upstream drop already exceeds the entered budget. Full native exports retain the original null; this does not approve a conductor or installation.

Decimal results are approximate. Inputs stay in this browser tab.

How it works

Electrical arithmetic on the values you enter, with every input and result recorded exactly. It does not design an installation, select a cable or check national regulations. All prefilled numbers are arbitrary hypothetical examples, not cable specifications or approved limits. Enter one-way route length; return is included once for DC and single-phase. Enter real W, not VA; three-phase voltage is line-to-line and loads must be balanced. AC assumes lagging power factor and a steady scalar approximation. Leading, unbalanced, harmonic and starting conditions are outside this model. Operating R/X must come from your own verified conductor data. Upstream drop consumes the entered budget. No upper mathematical length for zero coefficient does not imply a safe infinite cable. Not defined means either no finite bound or an already exhausted budget; check the separate flags. A zero receiving voltage is a numerical endpoint, not a usable design. No thermal ampacity, protection, earthing, short-circuit, installation or country-law approval.

Worked example

With these example values the calculator gives the result below. You can change any value in the form above.

Inputs

Circuit model
Two-wire DC
Load input
Entered current (A)
Entered source voltage (V)
24
Entered current (A)
10
One-way route length (m)
10
Actual operating resistance per conductor (Ω/km)
10
Entered upstream voltage drop (V)
0
Own entered voltage-drop criterion
10
Display decimal places (0–8)
2

Result

Calculated current (A)
10
Entered power factor
1
Effective drop coefficient (Ω/km)
10
Route voltage drop (V)
2
Upstream voltage drop (V)
0
Total voltage drop (V)
2
Voltage drop (%)
8.33
Model receiving voltage (V)
22
Entered drop budget (V)
2.4
Budget after upstream drop (V)
2.4
Mathematical maximum one-way length
12
No finite length bound in criterion (1=yes, 0=no)
0

Frequently asked questions

How do I calculate voltage drop in a cable?

Enter the voltage, real power, power factor, one-way route length and your verified operating resistance and reactance, then calculate. The voltage drop calculator returns the route drop, total drop, percentage and receiving voltage and checks them against your entered criterion.

Should I enter the one-way or the total cable length?

Enter the one-way route length. For DC and single-phase circuits the return conductor is included once by the calculation.

Do I enter power in watts or VA for the voltage drop calculation?

Enter real power in watts, not VA. For three-phase circuits the voltage is line-to-line and the loads must be balanced.

What assumptions does the voltage drop calculator make for AC?

AC assumes a lagging power factor and a steady scalar approximation. Leading, unbalanced, harmonic and starting conditions are outside the model.

How does upstream voltage drop affect the result?

Upstream drop consumes the entered drop budget, and the maximum one-way length is calculated from what is left. If no length is defined, either there is no finite bound or the budget is already exhausted; separate flags show which.

Where do the resistance and reactance values come from?

Operating R and X must come from your own verified conductor data. The prefilled numbers are arbitrary hypothetical examples, not cable specifications or approved limits.

Does the voltage drop calculator approve a cable size?

No. It gives no thermal ampacity, protection, earthing, short-circuit, installation or country-law approval and does not select a cable.