Approximate dew point and humidity scenarios
Calculate the approximate dew point from temperature and relative humidity, or humidity from dew point, in °C or °F, and build a scenario table.
Edit the example values, press Calculate and download the result if you need it. Editing or resetting clears the result; nothing is automatically saved.
Result
Formula / calculation:
Examples are arbitrary hypothetical values. Choose °C or °F for ALL temperature inputs; changing the unit keeps entered numbers, so edit them deliberately. All output temperatures are °C. Computational limits: air, supplied dew point and surface −40 to 50 °C; calculated dew point outside this range is refused. This boundary is not an accuracy guarantee. Approximation over liquid water, including below 0 °C: NOT frost point, ice, flue gas, wet bulb or pressure-corrected measurement. RH=0 gives zero vapour pressure and an undefined dew point, shown as undefined rather than 0 °C. Known dew point must not exceed air temperature. A surface ratio can exceed 100%; the threshold air RH can also exceed 100% for a warmer surface. Neither is clamped or a detected moisture event. Surface comparison uses unchanged vapour pressure and does not model walls, airflow or drying. No mould, health, habitability, structural or legal assessment. Tables compute your stated start/end/step, up to 101 rows; an off-grid endpoint is not invented. Scientific relations: NOAA/NWS vapour-pressure and dew-point equation notes; isolated formula constants 6.11, 7.5, 237.3 only. Own implementation and wording; no source script, table, prose or graphic redistributed. NOAA/NWS does not endorse this tool; this is not an official government product. Table samples follow the entered decimal start, end and step; the end appears only when it lies on that grid. Table enumeration does not change the stated physical model or measurement accuracy.
Decimal results are approximate. Inputs stay in this browser tab.
Sources
How it works
Own implementation of cited approximate liquid-water humidity equations; no frost, mould, health or building assessment. Examples are arbitrary hypothetical values. Choose °C or °F for ALL temperature inputs; changing the unit keeps entered numbers, so edit them deliberately. All output temperatures are °C. Computational limits: air, supplied dew point and surface −40 to 50 °C; calculated dew point outside this range is refused. This boundary is not an accuracy guarantee. Approximation over liquid water, including below 0 °C: NOT frost point, ice, flue gas, wet bulb or pressure-corrected measurement. RH=0 gives zero vapour pressure and an undefined dew point, shown as undefined rather than 0 °C. Known dew point must not exceed air temperature. A surface ratio can exceed 100%; the threshold air RH can also exceed 100% for a warmer surface. Neither is clamped or a detected moisture event. Surface comparison uses unchanged vapour pressure and does not model walls, airflow or drying. No mould, health, habitability, structural or legal assessment. Tables compute your stated start/end/step, up to 101 rows; an off-grid endpoint is not invented. Scientific relations: NOAA/NWS vapour-pressure and dew-point equation notes; isolated formula constants 6.11, 7.5, 237.3 only. Own implementation and wording; no source script, table, prose or graphic redistributed. NOAA/NWS does not endorse this tool; this is not an official government product.
Worked example
With these example values the calculator gives the result below. You can change any value in the form above.
Inputs
- Calculation mode
- Air temperature and relative humidity
- Unit for all entered temperatures
- Celsius (°C)
- Air temperature in selected unit
- 20
- Relative humidity (%)
- 50
- Surface comparison
- Own surface temperature
- Surface temperature in selected unit
- 10
- Display decimal places (0–8)
- 2
Result
- Entered air temperature (°C)
- 20
- Relative humidity (%)
- 50
- Approximate saturation pressure (hPa)
- 23.39
- Approximate vapour pressure (hPa)
- 11.69
- Approximate dew point
- 9.27
- Entered surface temperature (°C)
- 10
- Surface minus dew point (°C)
- 0.73
- Surface vapour/saturation ratio (%)
- 95.21
- Air RH at surface saturation (%)
- 52.52
- Mathematical surface saturation comparison
- No
Frequently asked questions
How do I calculate the dew point from relative humidity?
Enter the air temperature and relative humidity and calculate. For example, 20 °C and 50% RH give an approximate dew point of 9.27 °C, using NOAA/NWS vapour-pressure and dew-point equation notes.
What temperature range does the dew point calculator accept?
Air, supplied dew point and surface temperatures must be between -40 and 50 °C. A calculated dew point outside this range is refused. This boundary is not an accuracy guarantee.
Can I use Fahrenheit?
Yes. Choose °C or °F for all temperature inputs. Changing the unit keeps the entered numbers, so edit them deliberately, and all output temperatures are in °C.
What happens at 0% relative humidity?
RH of 0 gives zero vapour pressure and an undefined dew point, shown as undefined rather than 0 °C.
Can the calculator compare a surface temperature?
Yes. It reports the surface minus dew point, the surface vapour to saturation ratio and the air RH at surface saturation. The ratio can exceed 100% and is not clamped or treated as a detected moisture event.
Does the tool assess mould or frost?
No. It is an approximation over liquid water, including below 0 °C, and is not the frost point, ice, flue gas, wet bulb or pressure-corrected measurement. There is no mould, health, habitability, structural or legal assessment.
How many rows can a scenario table have?
Tables compute your stated start, end and step, up to 101 rows. An off-grid endpoint is not invented.